Our company promises all buyers of the first-class products and solutions as well as most satisfying post-sale support. We warmly welcome our regular and new shoppers to join us for Ac Filter Capacitor Bank , Low-Frequency Induction Furnace Capacitor , Ul Approved Film Capacitor , We warmly welcome all standpoint inquiries from home and abroad to cooperate with us, and anticipate your correspondence.
Wholesale Ac-Filter For Ups Systems - Self-healing film Power capacitor bank for rail traction – CRE Detail:

Technical data

Operating temperature range Max.Operating temperature.,Top,max:  + 70℃Upper category temperature: +60℃Lower category temperature: -40℃
capacitance range

100μF~20000μF

Un/ Rated voltage Un

600V.DC~4000V.DC

Cap.tol

±5%(J) ;±10%(K)

Withstand voltage

Vt-t

1.5Un DC/60S

Vt-c

1000+2×Un/√2 (V.AC)  60S(min 3000 V.AC)

Over Voltage

1.1Un(30% of on-load-dur.)

1.15Un(30min/day)

1.2Un(5min/day)

1.3Un(1min/day)

1.5Un(100ms every time,1000times during the lifetime)

Dissipation factor

tgδ≤0.003  f=100Hz

  tgδ0≤0.0002

ESL

<150 nH

Flame retardation

UL94V-0

Maximum aititude

2000m

When the altitude is above 2000m to below 5000m, it is necessary to consider the use of reduced amount.(for each increase of 1000m, the voltage and current will be reduced by 10%)

Life expectancy

100000h(Un; Θhotspot ≤70 °C )

Reference standard

IEC 61071 ;IEC 61881;

Feature

1. Metal shell encapsulation, dry resin infusion;

2. Copper nut / screw leads, easy installation;

3. Large capacity, small size;

4. Resistance to high voltage, with self-healing;

5. High ripple current, high dv / dt withstand capability.

Like other CRE products , the series capacitor have UL certificate and 100% burn-in tested.

Application

1. Railway traction;
2. Pv inverter;
3. wind power converter;
4. All kinds of frequency converter and inverter power supply;
5. Pure electric and hybrid cars;
6. SVG, SVC devices
7. other kinds of power quality management.

Typical circuit

1 2

Life expectancy

3

Outline drawing

4

Voltage Un   800V.DC  Us 1200V  Ur 200V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms(A)50℃@10KHz ESR     (mΩ) @1KHz Rth    (K/W) Weight   (Kg)
4000 340 125 190 5 20.0 120 1.1 0.9 17.6
8000 340 125 350 4 32.0 180 0.72 0.6 31.2
6000 420 125 245 5 30.0 150 0.95 0.7 26.4
10000 420 125 360 4 40.0 200 0.72 0.5 39.2
12000 420 235 245 4 48.0 250 0.9 0.3 49.6
20000 420 235 360 3 60.0 300 0.6 0.3 73.6

 

Voltage Un   1200V.DC  Us 1800V  Ur 300V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms(A)50℃@10KHz ESR     (mΩ) @1KHz Rth    (K/W) Weight   (Kg)
2500 340 125 190 8 20.0 120 1.1 0.9 17.6
3300 340 125 245 8 26.4 150 0.95 0.7 22.4
5000 420 125 300 7 35.0 180 0.8 0.6 32.8
7500 420 125 430 5.5 41.3 200 0.66 0.6 44.8
5000 340 235 190 8 40.0 200 1.1 0.3 32.8
10000 340 235 350 6 60.0 250 0.8 0.3 58.4
5000 420 235 175 8 40.0 200 1 0.4 36
7500 420 235 245 7 52.5 250 0.9 0.3 49.6
10000 420 235 300 7 70.0 250 0.8 0.3 61.6
15000 420 235 430 5 75.0 300 0.6 0.3 84

 

Voltage Un   1500V.DC  Us 2250V  Ur 450V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms(A)50℃@10KHz ESR     (mΩ) @1KHz Rth    (K/W) Weight   (Kg)
1200 340 125 190 10 12.0 120 1.1 0.9 17.6
3000 340 125 420 8 24.0 180 0.66 0.7 37.6
2000 420 125 245 10 20.0 150 0.95 0.7 26.4
4000 420 125 430 8 32.0 200 0.66 0.6 44.8
5000 340 235 350 8 40.0 250 0.8 0.3 58.4
4000 420 235 245 10 40.0 250 0.9 0.3 49.6
8000 420 235 430 8 64.0 300 0.6 0.3 84

 

Voltage Un   2000V.DC  Us 3000V  Ur 600V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms(A)50℃@10KHz ESR     (mΩ) @1KHz Rth    (K/W) Weight   (Kg)
1000 340 125 245 12 12.0 150 0.95 0.7 22.4
1500 340 125 350 10 15.0 180 0.72 0.6 31.2
2000 420 125 360 10 20.0 200 0.72 0.5 39.2
2400 420 125 430 9 21.6 200 0.66 0.6 44.8
3200 340 235 350 10 32.0 250 0.8 0.3 46.4
4000 420 235 360 10 40.0 280 0.7 0.3 58.4
4800 420 235 430 9 43.2 300 0.6 0.3 67.2

 

Voltage Un   2200V.DC  Us 3300V  Ur 600V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms    (A)max ESR     (mΩ) Rth    (K/W) Weight   (Kg)
2000 420 235 245 12 24 150 0.9 0.740740741 40
2750 420 235 300 10 27.5 200 0.8 0.46875 49.6
3500 420 235 360 10 35 200 0.7 0.535714286 58.4

 

Voltage Un   3000V.DC  Us 4500V  Ur 800V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms    (A)max ESR     (mΩ) Rth    (K/W) Weight   (Kg)
1050 420 235 245 20 21 150 0.9 0.740740741 40
1400 420 235 300 15 21 200 0.8 0.46875 49.6
1800 420 235 360 15 27 200 0.7 0.535714286 58.4

 

Voltage Un   4000V.DC  Us 6000V  Ur 1000V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms    (A)max ESR     (mΩ) Rth    (K/W) Weight   (Kg)
600 420 235 245 20 12 150 0.9 0.740740741 40
800 420 235 300 20 16 200 0.8 0.46875 49.6
1000 420 235 360 20 20 200 0.7 0.535714286 58.4

 

Voltage Un   2800V.DC  Us 4200V  Ur 800V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms(A)50℃@10KHz ESR     (mΩ) @1KHz Rth    (K/W) Weight   (Kg)
2×1000 560 190 310 20 2×20 2×350 1 0.2 60

 

Voltage Un   3200V.DC  Us 4800V  Ur 900V
Cn  (μF) W   (mm) T  (mm) H    (mm) dv/dt (V/μS) Ip       (KA) Irms(A)50℃@10KHz ESR     (mΩ) @1KHz Rth    (K/W) Weight   (Kg)
2×1200 340 175 950 15 2×18 2×200 1.0 0.5 95

Product detail pictures:

Wholesale Ac-Filter For Ups Systems - Self-healing film Power capacitor bank for rail traction – CRE detail pictures

Wholesale Ac-Filter For Ups Systems - Self-healing film Power capacitor bank for rail traction – CRE detail pictures

Wholesale Ac-Filter For Ups Systems - Self-healing film Power capacitor bank for rail traction – CRE detail pictures


Related Product Guide:

All we do is often involved with our tenet " Purchaser to start with, Rely on initially, devoting over the food stuff packaging and environmental defense for Wholesale Ac-Filter For Ups Systems - Self-healing film Power capacitor bank for rail traction – CRE , The product will supply to all over the world, such as: Canberra, Palestine, Sydney, When you are keen on any of our goods following you view our product list, be sure to feel free to make contact with us for inquiries. You'll be able to send us emails and get in touch with us for consultation and we shall respond to you as soon as we're able to. If it's convenient, you could find out our address in our web site and come to our enterprise. or additional information of our products by yourself. We're generally ready to build lengthy and steady co-operation relations with any possible shoppers within the associated fields.
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Darlene from Netherlands - 2017.02.28 14:19
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Kama from Honduras - 2017.04.28 15:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us: