Battery-ultracapacitor hybrid energy storage unit
Specification
1) Up to 100000 charge cycles. It shall be workable for ten years.
2) Non-explosive: Physical reaction instead of chemical reaction. Much safer than chemistry-based batteries.
3) Energy density is 75-220wh/kg. Lots of power in a small unit.
4) 80% charge in 5-15 minutes! Quick.
5) -40 to 70℃ range of operating temperature. Suitable for extreme conditions.
6) Low self-discharge. SOC >80% storing 180 days after full charge
Electrical performance and safety performance
No |
Item |
Test method |
Test requirement |
Remark |
1 |
Standard charging mode | At room temperature, the product is charged at a constant current of 1C. When the product voltage reaches the charging limit voltage of 16V, the product is charged at constant voltage until the charging current is less than 250mA. |
/ |
/ |
2 |
Standard discharge mode | At room temperature, the discharge will be stopped when the product voltage reaches the discharge limit voltage of 9V. |
/ |
/ |
3 |
Rated capacitance |
1. The product is charged according to the standard charging method. |
The product capacity shall be no less than 60000F |
/ |
2. Stay 10min | ||||
3. The product discharges according to the standard discharge mode. | ||||
4 |
Internal resistance |
Ac internal resistance tester tests, precision: 0.01 m Ω |
≦5mΩ |
/ |
5 |
Discharge of high temperature |
1. The product is charged according to the standard charging method. |
Discharge capacity should ≥ 95% rated capacity, product appearance without deformation, no burst. |
/ |
2. Put the product into the incubator of 60±2℃ for 2H. | ||||
3. Discharge the product according to the standard discharge mode, recording discharge capacity. | ||||
4. After the discharge, the product will be taken out under normal temperature for 2 hours, and then visual appearance. | ||||
6 |
Low-temperature discharge |
1. The product is charged according to the standard charging method. |
discharge capacity≧70% no change on rated capacity, cap appearance, no burst |
/ |
2. Put the product into the incubator of -30±2℃ for 2H. | ||||
3. Discharge the product according to the standard discharge, recording discharge capacity. | ||||
4. After the discharge, the product will be taken out under normal temperature for 2 hours, and then visual appearance. | ||||
7 |
Cycle life |
1. The product is charged according to the standard charging method. |
No less than 20,000 cycles |
/ |
2. Stay 10min. | ||||
3. The product discharges according to the standard discharge mode. | ||||
4. Charge and discharge according to the above charging and discharging method for 20,000 cycles, until the discharge capacity is less than 80% of the initial capacity, the cycle is stopped. | ||||